Heating
With low cost and good insulation effect, DC inverter heat pumps have become a new fashion for comfortable heating in households.
With low cost and good insulation effect, DC inverter heat pumps have become a new fashion for comfortable heating in households.
DC inverter heat pumps have the function of heating in winter and cooling in summer, with stable and reliable performance. It also features environmentally friendly and energy-saving, suitable for use throughout the year.
DC inverter heat pumps can be used flexibly to provide both hot water and heating.
Only the refrigerant circulation system is placed in the outdoor unit. The indoor unit can be installed in a bathroom, kitchen or utility room. Since all the waterway systems are on the indoor side, there won’t be troubled by icing even in extremely cold winters. So split machine will work more safely and reliably in cold regions.
It is monoblock design, space-saving and easy to install. Simply connect the waterway and power supply to start up and operate. It runs automatically and stably all day, and has reliable performance.
Combining WiFi technology with a DC inverter heat pump unit achieves the control of heating temperature, which can save energy and improve quality of life and efficiency.
The remote control allows you to adjust the temperature anytime and anywhere, achieving high efficiency and energy conservation while ensuring the normal operation of a DC inverter heat pump.
Suoher experts will communicate with you in time to solve your confusion
Clarify the minimum ambient temperature at which the unit will operate. The lower the ambient temperature, the less heat can be output by a unit with the same power. Therefore, in winter with lower ambient temperature, high-powered units should be used appropriately to ensure that there is still sufficient heat supply to meet demand at the lowest ambient temperature.
Define the size of the space that needs heating is crucial. The larger the space, the more heat the equipment needs to output, which corresponds to a larger equipment model.
Determine insulation effect of space to be heated. The better insulation effect of the house, the less heat loss and power of the equipment required.
Define the heating terminal equipment used in the room. Different terminal heating equipment require different heating water temperatures. Typically, radiant floor heating requires a heating water temperature of 35 degrees, fan coil units require 45 degrees, while radiators require a water temperature of over 50 degrees.
Become our partner and help you achieve success in the field of heat pumps. Join Suoher in striving for 2050 net zero emissions!
Provide us with your heat pump procurement requirements or drawings, and we will keep your business information confidential!